Sectionalizer, Auto Circuit Breaker, Distribution manufacturer / supplier in China, offering 15kv/27kv/38kv Recloser Wtith IEC61850 and DNP3.0 for Distribution and Substation, Pasgt Tactical M88 U. S. Army Steel Replica Anti-Riot Helmet Full Head Coverage with Adjustable Chin Strap for Personal Safety of Airsoft Hunting Paint Ball Bb, Od8mm Stainless Steel Bowfishing Line Guiding Rod with Ceramic Eyelet Accessory Fit Reel Seat Mount for Fishing Bow Fishing Slingshot and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Breaker & Protector Arrester China 27kv Line Surge Arrester for Distribution Overhead Line

China 27kv Line Surge Arrester for Distribution Overhead Line

Get Latest Price
Min. Order / Reference FOB Price
100 Piece US $500.00/ Piece
Local Area: Ningbo, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Installation: Tandem Arrester

TABLE OF MINIMUM TECHNICAL DATAZINC 27 KV metaLLIC OXIDE LINE ARRESTORITEMDEscriptION UNITREQUIREDGUARANTEED11 GENERAL DATA1.1Manufacturer INDICATEHEMG1.2Country of Origin INDICATECHINA1.3Model INDICATEYH10W-271.4Type OZNZNO Lightning arrester1.5Standard IEC 60099-4IEC 60099-41.6Mounting OUTDOOROUTDOOR1.7Class 2 221.8Installation altitude m.s.n.m. MOSLMAJOR THAN 400040001.9Type of conductor of the line OUTDOOROUTDOOR1.10.Line conductor section (*) MM225 TO 12025 TO 1202NOMINAL DATA AND CHARACTERISTICS2.1Rated frequency (fr) HZ60602.2System voltage kV KV22.922.92.3Rated voltage (Ur) KV27272.4Continuous operating voltage (MCOV) KV22222.5Temporary overvoltage at 1 s.KV30302.6Rated discharge current KA10102.7Energy dissipation capacity (double pulse) kJ / kVKJ/KV4.5@UR MIMIMUM4.752.8Maximum residual voltage to the maneuver type impulse at 500 A KV57572.9Maximum residual voltage to the atmospheric discharge impulse to: 5kA KV6767 10kA KV7272 20kA KV80802.10.Body Isolator Silicone Rubber SILICON RUBBERSILICON RUBBER2.11The BIL of the equipment to be protected KV1701702.12Permissible static and dynamic load According to IEC 60099-4 Second Edition (2004-5) NmINDICATE5002.13LEAKAGE DISTANCEMM 100010002.14metal parts protected against corrosion by hot dip galvanizing YESYES2.15Type test (delivery of similar lightning conductor certificate YESYES2.16Integrated Disconnector with Impeller Cartridge according to IEC YESYES2.17Connection terminal to conductor type staple suspension for live line work with installation with shotgun type YESYES2.18Grounding accessories that should include: 25 mm2 copper wire, shackles and connectors suitable for grounding. YESYES3COMPLEMENTARY INFORMATION3.1Dimensional plane equipment YESYES3.2Drawing of the rating plate YESYES3.3Complete connection and metering plan from the clamp to the ground connection. YESYES (*) You should consider 30 staples from 70 to 120 mm2 and the rest from 35 to 70 mm2 YES

Specification of MCOV 106/290,10KA LINE Lightning arrestor

1GENERAL DATAUnit Data 1.1MODEL Y10W1.2TYPE OZN metaLLIC1.3STANDARD IEC 60099-4 1.4INSTALLATION OUTDOOR1.5ALTITUDE OF INSTALLATIONm.s.n.m.16001.6TYPE OF CABLE OF LINE AAAC1.7SECTION OF THE CABLEmm2185, 211 and 2402CHARACTERISTICS 2.1Frequency (f)Hz602.2Voltage of the systemkV1452.3Nominal Voltage (Ur)kV1322.4Continuous operating voltage (MCOV).kV1062.5Temporary overvoltage at 1s.KV (minimum)1492.6Nominal discharge current.kA102.7Energy dissipation capacity (double impulse).KJ/KV (minimum)4.5 @ Ur2.8Maximum residual voltage to the maneuver type impulse at 1000A.kV2902.9Maximum residual voltage to the atmospheric discharge impulse to:5 kAkV(maximum)330 10 kAkV(maximum)355 20 kAkV(maximum)3902.10Housing of the insulator (body) Silicon rubber2.11Insulation level of the surge arresterkV(minimum)6502.12Permissible static and dynamic load according to IEC 60099-4.Nm60002.13Leakage distancemm (minimum)38002.14metal parts protected against corrosion by hot galvanizing. Yes2.15Type test (delivery of similar lightning conductor certificate). Yes2.16Disconnection device between the lightning arrestor and earth in case of failure of the lightning conductor, acting according to the inverse time curve current vs time (presenting curve). Yes2.17Complete accessory for the installation of the lightning conductor from the arrester to the grounding. Yes2.18Connection terminal to phase conductor type suspension clamp. Yes Brand. HEMG Manufacturer's catalog number (this number should be engraved in high relief on the clamp). CT2018XXXX Tinned copper flexible cable YES Material. AAAC Section of the line cablemm2185-240 Range of angle of use.°30 Burst load and minimum slipKn111 Standard of manufacture ASTM 153, IEEE C135.61 or similar IEEE C135.612.19Downhill hardware and grounding accessories that should include: shackles and connectors suitable for grounding. YES Brand. HEMG2.20Flexible tinned copper cable. YES Brand. HEMG Cable for grounding (section)mm2 (minimum)25MM2 Cable length per surge arrester m (minimum)5M

Specification of MCOV 57/156,10KA LINE Lightning arrestor

ITEMDESCRIPCIONUNIT DATA1GENERAL DATA 1.1Model. Y10W1.4Kind. OZN1.5Standard IEC60099-41.6Installation OUTDOOR1.8Altitude of Installation.m.o.s.l45001.9Type of line cable AAAC1.1Line conductor section.mm2 70-1202NOMINAL DATA AND CHARACTERISTICS. 2.1Assigned frequency (f).hz602.2System Voltagekv602.3Rated voltage (Ur).kv722.4Continuous operating voltage (MCOV).kv572.5Temporary overvoltage at 1s.kv (minimum)812.6Nominal discharge current.ka102.7Energy dissipation capacity (double impulse).kj/kv (minimum)4.5@UR2.8Maximum residual voltage to the maneuver type impulse at 1000A.kv1572.9Maximum residual stress to the atmospheric discharge impulse to:- 5 kA.KV (max)178 -10 kA.KV (max)1922.1-20 kA.KV (max)2112.11Body isolator. SILICON RUBBER2.12Isolation level of the lightning conductor.N-m6000Permissible static and dynamic load according to IEC 60099-4.2.13leakage distancemm23002.14metal parts protected against corrosion by hot galvanizing YES2.15Type test (delivery of similar lightning rod certificate) YES2.16Disconnection device between the lightning arrestor and earth in case of failure of the lightning conductor, acting according to the inverse time curve current vs time (presenting curve). YES2.17Complete accessory for the installation of the lightning conductor from the driver to the grounding. YES2.18Connection terminal to suspension type staple phase conductor YES Brand HEMG Manufacturer's catalog number (this number must be engraved in high relief on the staple) CT2018XXXX Material ALUMINUM ALLOY cable section 70-120 Usage angle range 30 Breakage load and minimum slip 76 Manufacturing standard ASTM153/IEEEC135.61 2.19Downhill hardware and grounding accessories that should include: shackles and connectors suitable for grounding YES Brand HEMG2.2Tinned copper flexible cable YES BRAND HEMG SECTION OF THE CABLEMM2 MINIMUM25 LENGHT OF THE CABLE FOR EACH SURGE ARRESTERMTS (MINIMUM)53.3Plate of characteristics plate YES