Gynecological Examination Table, Examination Table, Examination Bed Electric Operation Table Gynecol manufacturer / supplier in China, offering My-I013 Electric Operating Table Gynecology, New My-S029o-N Top Supplier Wholesale Full Body Massage Chair Price at Low Price, New My-A010A-N Portable USB Convex Probe Ultrasound System (Smallest Ultrasound) and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | Contact Supplier |
Local Area: | Guangzhou, Guangdong, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, D/P, PayPal, WesternUnion, Small-amountpayment |
Classification: | Imaging Diagnostic Equipment |
---|---|
Type: | X Ray Equipment |
Certification: | CE, ISO13485 |
ITEMCONTENTSINDEXDemand of power supplyCapacityTwo-phase 30KVAVoltage, Frequency380V/220V± 10%50HZ ± 0.5HzIntemal resistance2Ω (380V) 0.6 Ω (220V)power supplyAdjustable range380± 10% at220V being adjustable continuouslyRadiographVoltage50-90KVcurrent)Small focus:15mA, Big focus: 30mA 60mA 100mAtime0.04~6.35s 23grades together grading a according to R10 coefficientHigh-voltage generatorCapacity7KVAMax DC output voltage90KVMax DC output current100mAX-Ray tubeModel0xD4-2.9/100FocusSmall focus 1.8x 1.8mm big focus4.3x 4.3mmRadiographic
tableLengthx widthx height of bed surface2000mmx 665mmx 700mmMoving range of bed surface640mm in Length, 200mm in breadthRay-filter of tableTravel in length ≥ 50mmGrid density N=28Convergence distance f. =100cmGrid ratio r=8Column of X-ray tube unitMoving Longitudinally along
Radiographic table1000mm or 1800mmDistance to friend as moving up and down (along column)650~1800mmRotary around the center of cross arm± 180°Rotary around the shaft line of X-ray annular tubes-10° ~60° ~ +120°Max size of cassette356mmx 432mm(14″ x 17″ )
ITEMCONTENTSINDEXDemand of power supplyCapacityTwo-phase 30KVAVoltage, Frequency380V/220V± 10%50HZ ± 0.5HzIntemal resistance2 Ω (380V) 0.6 Ω (220V)power supplyAdjustable range380 ± 10% at220V being adjustable continuouslyRadiographVoltage50-90KVcurrent)Small focus:15mA, Big focus: 30mA 60mA 100mAtime0.04~6.35s 23grades together grading a according to R10 coefficientHigh-voltage generatorCapacity7KVAMax DC output voltage90KVMax DC output current100mAX-Ray tubeModel0xD4-2.9/100FocusSmall focus 1.8 x 1.8mm big focus4.3 x 4.3mmRadiographic
tableLength x width x height of bed surface2000mm x 665mm x 700mmMoving range of bed surface640mm in Length, 200mm in breadthRay-filter of tableTravel in length ≥ 50mmGrid density N=28Convergence distance f. =100cmGrid ratio r=8Column of X-ray tube unitMoving Longitudinally along
Radiographic table1000mm or 1800mmDistance to friend as moving up and down (along column)650~1800mmRotary around the center of cross arm± 180 °Rotary around the shaft line of X-ray annular tubes-10 ° ~60 ° ~ +120 °Max size of cassette356mm x 432mm(14 ″ x 17 ″ )